<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0" xmlns:media="http://search.yahoo.com/mrss/" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:itunes="http://www.itunes.com/dtds/podcast-1.0.dtd">
    <channel>
        <itunes:owner>
            <itunes:name>Alfa Laval - Energy</itunes:name>
            <itunes:email>alfa.laval@alfalaval.com</itunes:email>
        </itunes:owner>
        <title>Alfa Laval - Energy</title>
        <link>https://energy.alfalaval.com</link>
        <description></description>
        <language>en-us</language>
        <generator>Visualplatform</generator>
        <docs>http://blogs.law.harvard.edu/tech/rss</docs>
        <itunes:author>Alfa Laval - Energy</itunes:author>
        <itunes:type>episodic</itunes:type>
        <itunes:explicit>no</itunes:explicit>
        <itunes:image href="https://energy.alfalaval.com/files/rv0.0/sitelogo.gif"/>
        <image>
            <url>https://energy.alfalaval.com/files/rv0.0/sitelogo.gif</url>
            <title>Alfa Laval - Energy</title>
            <link>https://energy.alfalaval.com</link>
        </image>
        <atom:link rel="self" href="https://energy.alfalaval.com/podcast/tag/auxiliary cooling"/>
        <atom:link rel="next" href="https://energy.alfalaval.com/podcast/tag/auxiliary cooling?tag=auxiliary+cooling&amp;p=2&amp;podcast%5fp=t&amp;https="/>
        <item>
            <enclosure url="http://energy.alfalaval.com/60650857/63457349/98b815bcdb5545f513be4e8d6b4d5001/video_medium/alfa-laval-wetsurface-maximum-video.mp4?source=podcast" type="video/mp4" length="6441812"/>
            <title>Alfa Laval WetSurface – Maximum cooling efficiency and lowest possible output</title>
            <link>http://energy.alfalaval.com/alfa-laval-wetsurface-maximum</link>
            <description>&lt;p&gt;Unlike traditional air-cooled heat exchangers, the tube bundles in a WSAC are sprayed with water and use evaporative cooling to reject the heat from the process medium. This results in superior cooling and a WSAC is both significantly smaller, has a lower power consumption and lower output temperature than an air cooler.&lt;br&gt;&amp;nbsp;&lt;br&gt;For more details visit&amp;nbsp;&lt;a href="https://www.alfalaval.com/wsac"&gt;Alfa Laval - Niagara Wet Surface Air Coolers&lt;/a&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://energy.alfalaval.com/alfa-laval-wetsurface-maximum"&gt;&lt;img src="http://energy.alfalaval.com/60650857/63457349/98b815bcdb5545f513be4e8d6b4d5001/standard/download-3-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://energy.alfalaval.com/photo/63457349</guid>
            <pubDate>Fri, 26 Jun 2020 08:22:27 GMT</pubDate>
            <media:title>Alfa Laval WetSurface – Maximum cooling efficiency and lowest possible output</media:title>
            <itunes:summary>Unlike traditional air-cooled heat exchangers, the tube bundles in a WSAC are sprayed with water and use evaporative cooling to reject the heat from the process medium. This results in superior cooling and a WSAC is both significantly smaller, has a lower power consumption and lower output temperature than an air cooler.For more details visitAlfa Laval - Niagara Wet Surface Air Coolers</itunes:summary>
            <itunes:subtitle>Unlike traditional air-cooled heat exchangers, the tube bundles in a WSAC are sprayed with water and use evaporative cooling to reject the heat from the process medium. This results in superior cooling and a WSAC is both significantly smaller, has...</itunes:subtitle>
            <itunes:author>Alfa Laval - Energy</itunes:author>
            <itunes:duration>00:57</itunes:duration>
            <media:description type="html">&lt;p&gt;Unlike traditional air-cooled heat exchangers, the tube bundles in a WSAC are sprayed with water and use evaporative cooling to reject the heat from the process medium. This results in superior cooling and a WSAC is both significantly smaller, has a lower power consumption and lower output temperature than an air cooler.&lt;br&gt;&amp;nbsp;&lt;br&gt;For more details visit&amp;nbsp;&lt;a href="https://www.alfalaval.com/wsac"&gt;Alfa Laval - Niagara Wet Surface Air Coolers&lt;/a&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://energy.alfalaval.com/alfa-laval-wetsurface-maximum"&gt;&lt;img src="http://energy.alfalaval.com/60650857/63457349/98b815bcdb5545f513be4e8d6b4d5001/standard/download-3-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://energy.alfalaval.com/v.ihtml/player.html?token=98b815bcdb5545f513be4e8d6b4d5001&amp;source=podcast&amp;photo%5fid=63457349" width="625" height="352" type="text/html" medium="video" duration="57" isDefault="true" expression="full"/>
            <media:thumbnail url="http://energy.alfalaval.com/60650857/63457349/98b815bcdb5545f513be4e8d6b4d5001/standard/download-3-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://energy.alfalaval.com/60650857/63457349/98b815bcdb5545f513be4e8d6b4d5001/standard/download-3-thumbnail.jpg/thumbnail.jpg"/>
            <category>air cooled heat exchanger</category>
            <category>air cooler</category>
            <category>air cooling</category>
            <category>alfa laval</category>
            <category>auxiliary cooling</category>
            <category>closed-loop cooling</category>
            <category>condensing</category>
            <category>cooling capacity</category>
            <category>crude oil refinery</category>
            <category>dry cooling</category>
            <category>energy efficiency</category>
            <category>energy industry</category>
            <category>energy savings</category>
            <category>heat exchanger</category>
            <category>niagara blower</category>
            <category>oil and gas industry</category>
            <category>operating cost</category>
            <category>petrochemicals</category>
            <category>power industry</category>
            <category>process industry</category>
            <category>pulp and paper industry</category>
            <category>steel industry</category>
            <category>thermal performance</category>
            <category>wastewater cooling</category>
            <category>water cooling</category>
            <category>wet cooling</category>
        </item>
        <item>
            <enclosure url="http://energy.alfalaval.com/60445192/63279557/2a2e1a60182b9ec3651e6c2c13f3e82e/video_medium/alfa-laval-flexwater-enables-wsac-video.mp4?source=podcast" type="video/mp4" length="7787248"/>
            <title>Alfa Laval FlexWater – Enables WSAC operation with low-quality recycled water</title>
            <link>http://energy.alfalaval.com/alfa-laval-flexwater-enables-wsac</link>
            <description>&lt;p&gt;Thanks to the spacing between the tubes, the nozzle design and the absence of cooling tower fill, a Niagara wet surface air cooler can operate on water of low quality, e.g. blowdown water from a cooling tower, treated wastewater or sea water.&lt;br&gt;&lt;br&gt;For more details visit&amp;nbsp;&lt;a href="https://www.alfalaval.com/wsac"&gt;Alfa Laval - Niagara Wet Surface Air Coolers&lt;/a&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://energy.alfalaval.com/alfa-laval-flexwater-enables-wsac"&gt;&lt;img src="http://energy.alfalaval.com/60445192/63279557/2a2e1a60182b9ec3651e6c2c13f3e82e/standard/download-3-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://energy.alfalaval.com/photo/63279557</guid>
            <pubDate>Mon, 15 Jun 2020 14:44:55 GMT</pubDate>
            <media:title>Alfa Laval FlexWater – Enables WSAC operation with low-quality recycled water</media:title>
            <itunes:summary>Thanks to the spacing between the tubes, the nozzle design and the absence of cooling tower fill, a Niagara wet surface air cooler can operate on water of low quality, e.g. blowdown water from a cooling tower, treated wastewater or sea water.For more details visitAlfa Laval - Niagara Wet Surface Air Coolers</itunes:summary>
            <itunes:subtitle>Thanks to the spacing between the tubes, the nozzle design and the absence of cooling tower fill, a Niagara wet surface air cooler can operate on water of low quality, e.g. blowdown water from a cooling tower, treated wastewater or sea water.For...</itunes:subtitle>
            <itunes:author>Alfa Laval - Energy</itunes:author>
            <itunes:duration>01:04</itunes:duration>
            <media:description type="html">&lt;p&gt;Thanks to the spacing between the tubes, the nozzle design and the absence of cooling tower fill, a Niagara wet surface air cooler can operate on water of low quality, e.g. blowdown water from a cooling tower, treated wastewater or sea water.&lt;br&gt;&lt;br&gt;For more details visit&amp;nbsp;&lt;a href="https://www.alfalaval.com/wsac"&gt;Alfa Laval - Niagara Wet Surface Air Coolers&lt;/a&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://energy.alfalaval.com/alfa-laval-flexwater-enables-wsac"&gt;&lt;img src="http://energy.alfalaval.com/60445192/63279557/2a2e1a60182b9ec3651e6c2c13f3e82e/standard/download-3-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://energy.alfalaval.com/v.ihtml/player.html?token=2a2e1a60182b9ec3651e6c2c13f3e82e&amp;source=podcast&amp;photo%5fid=63279557" width="625" height="352" type="text/html" medium="video" duration="64" isDefault="true" expression="full"/>
            <media:thumbnail url="http://energy.alfalaval.com/60445192/63279557/2a2e1a60182b9ec3651e6c2c13f3e82e/standard/download-3-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://energy.alfalaval.com/60445192/63279557/2a2e1a60182b9ec3651e6c2c13f3e82e/standard/download-3-thumbnail.jpg/thumbnail.jpg"/>
            <category>air cooled heat exchanger</category>
            <category>air cooler</category>
            <category>air cooling</category>
            <category>alfa laval</category>
            <category>auxiliary cooling</category>
            <category>closed-loop cooling</category>
            <category>condensing</category>
            <category>cooling capacity</category>
            <category>crude oil refinery</category>
            <category>dry cooling</category>
            <category>energy efficiency</category>
            <category>energy industry</category>
            <category>energy savings</category>
            <category>heat exchanger</category>
            <category>niagara blower</category>
            <category>oil and gas industry</category>
            <category>operating cost</category>
            <category>petrochemicals</category>
            <category>power industry</category>
            <category>process industry</category>
            <category>pulp and paper industry</category>
            <category>steel industry</category>
            <category>thermal performance</category>
            <category>wastewater cooling</category>
            <category>water cooling</category>
            <category>wet cooling</category>
        </item>
        <item>
            <enclosure url="http://energy.alfalaval.com/49543315/60459247/dbe126061f3b18dc63d9bdb93aa36fad/video_medium/alfa-laval-niagara-wsac-how-it-1-video.mp4?source=podcast" type="video/mp4" length="8734035"/>
            <title>Alfa Laval Niagara WSAC - How it works</title>
            <link>http://energy.alfalaval.com/alfa-laval-niagara-wsac-how-it-1</link>
            <description>&lt;p&gt;This animation demonstrates the working principle of the Alfa Laval Niagara Wet Surface Air Cooler.
&lt;p&gt;Alfa Laval Niagara Wet Surface Air Coolers (WSAC®) are custom built, closed-loop cooling and condensing systems that combine high performance, low operating costs, compact size and reliable operation. Renowned for their robust design and high efficiency, Alfa Laval Niagara WSACs are used in a large number of demanding industries. Their low water consumption and high cooling capacity have made them a popular choice in applications where low temperatures are required for process improvements.&lt;/p&gt;
&lt;p&gt;For more details visit&amp;nbsp;&lt;a href="https://www.alfalaval.com/wsac"&gt;Alfa Laval - Niagara Wet Surface Air Coolers&lt;/a&gt;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://energy.alfalaval.com/alfa-laval-niagara-wsac-how-it-1"&gt;&lt;img src="http://energy.alfalaval.com/49543315/60459247/dbe126061f3b18dc63d9bdb93aa36fad/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://energy.alfalaval.com/photo/60459247</guid>
            <pubDate>Wed, 12 Feb 2020 09:20:56 GMT</pubDate>
            <media:title>Alfa Laval Niagara WSAC - How it works</media:title>
            <itunes:summary>This animation demonstrates the working principle of the Alfa Laval Niagara Wet Surface Air Cooler.
Alfa Laval Niagara Wet Surface Air Coolers (WSAC®) are custom built, closed-loop cooling and condensing systems that combine high performance, low operating costs, compact size and reliable operation. Renowned for their robust design and high efficiency, Alfa Laval Niagara WSACs are used in a large number of demanding industries. Their low water consumption and high cooling capacity have made them a popular choice in applications where low temperatures are required for process improvements.
For more details visitAlfa Laval - Niagara Wet Surface Air Coolers</itunes:summary>
            <itunes:subtitle>This animation demonstrates the working principle of the Alfa Laval Niagara Wet Surface Air Cooler.
Alfa Laval Niagara Wet Surface Air Coolers (WSAC®) are custom built, closed-loop cooling and condensing systems that combine high performance, low...</itunes:subtitle>
            <itunes:author>Alfa Laval - Energy</itunes:author>
            <itunes:duration>02:20</itunes:duration>
            <media:description type="html">&lt;p&gt;This animation demonstrates the working principle of the Alfa Laval Niagara Wet Surface Air Cooler.
&lt;p&gt;Alfa Laval Niagara Wet Surface Air Coolers (WSAC®) are custom built, closed-loop cooling and condensing systems that combine high performance, low operating costs, compact size and reliable operation. Renowned for their robust design and high efficiency, Alfa Laval Niagara WSACs are used in a large number of demanding industries. Their low water consumption and high cooling capacity have made them a popular choice in applications where low temperatures are required for process improvements.&lt;/p&gt;
&lt;p&gt;For more details visit&amp;nbsp;&lt;a href="https://www.alfalaval.com/wsac"&gt;Alfa Laval - Niagara Wet Surface Air Coolers&lt;/a&gt;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://energy.alfalaval.com/alfa-laval-niagara-wsac-how-it-1"&gt;&lt;img src="http://energy.alfalaval.com/49543315/60459247/dbe126061f3b18dc63d9bdb93aa36fad/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://energy.alfalaval.com/v.ihtml/player.html?token=dbe126061f3b18dc63d9bdb93aa36fad&amp;source=podcast&amp;photo%5fid=60459247" width="625" height="352" type="text/html" medium="video" duration="140" isDefault="true" expression="full"/>
            <media:thumbnail url="http://energy.alfalaval.com/49543315/60459247/dbe126061f3b18dc63d9bdb93aa36fad/standard/download-2-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://energy.alfalaval.com/49543315/60459247/dbe126061f3b18dc63d9bdb93aa36fad/standard/download-2-thumbnail.jpg/thumbnail.jpg"/>
            <category>air cooled heat exchanger</category>
            <category>air cooler</category>
            <category>air cooling</category>
            <category>alfa laval</category>
            <category>auxiliary cooling</category>
            <category>closed-loop</category>
            <category>closed-loop cooling</category>
            <category>condensing</category>
            <category>cooling capacity</category>
            <category>dry cooling</category>
            <category>energy efficiency</category>
            <category>energy savings</category>
            <category>heat exchanger</category>
            <category>niagara blower</category>
            <category>oil and gas</category>
            <category>operating cost</category>
            <category>petrochemicals</category>
            <category>power industry</category>
            <category>process industry</category>
            <category>pulp and paper industry</category>
            <category>refinery</category>
            <category>steel industry</category>
            <category>thermal performance</category>
            <category>wastewater cooling</category>
            <category>water cooling</category>
            <category>wet cooling</category>
            <category>wet surface air cooler</category>
        </item>
    </channel>
</rss>
